Quick Details

  • Place of Origin: France
  • Brand Name: LANGLOIS
  • Model Number: MOTODIAG
  • Dimensions: 670 x 750 x 1180mm
  • Laminated bench-top: 670 x 750mm
  • Casters diam. 80mm: 4
  • 3-phase Hypra socket: on 5m mains cable
  • Weight: 80kg

Packaging & Delivery

Delivery Detail: 4 weeks

Specifications

This complete kit on casters can be used to simulate the faults which occur most frequently.

This complete kit on casters, comprising two back-to-back units and an asynchronous squirrel cage motor and a parking brake, can be used to simulate the faults which occur most frequently.
The principle and the instructions have been devised by teachers who want to propose a method for diagnosing faults.

PRINCIPLE
Faults are recreated when the teacher rotates a single switch. Students can take measurements or perform tests in complete safety, regardless of the fault type. Faults can be looked for inside the student unit and in the motor terminal. The unit is isolated from the mains by means of an insulation transformer. In addition, a TT earthing system is recreated on the secondary for safety reasons. Therefore,
even isolation faults are detected by a 30mA differential mechanism. All safety measures are implemented in order to protect individuals and equipment. (See the faults in the description of the teacher unit)

 

TEACHER SIDE UNIT
The teacher uses this lockable area to manage faults
activated by key switches he/she knows, and to view all of the simulator's workings. Thanks to indicator light.
The position of the switches and indicator lights remain invisible to students.
The following faults are possible:
• 3 faults involving «damaged coil». A resistor is connected in series with a coil to change its impedance. One switch per phase, or three switches.
• 3 faults involving «power being cut in a coil». The power is cut in a coil. One switch per phase, or three switches.
• 3 faults involving a «short-circuit in a coil». The coils are short-circuited two at a time. One switch per possibility or three switches.
• 3 faults involving «coil earthing». A coil is earthed. One switch per phase, or three switches.
• 1 fault on the brake. The power in the parking brake is cut.


STUDENT SIDE UNIT
This lockable area is used for starting up the simulator (if authorised by the teacher).

The transparent door gives the unit a highly didactic appearance.
The student control panel is simpler than the teacher control panel, offering standard normal operation indications.

This means that fault finding, testing and measurement are identical to reality in the field.

Transaction History of the Supplier

Below is the information about the supplier's transactions conducted via Alibaba.com. If you require further details regarding the transaction data, please contact the supplier directly.

Transaction Overview

Transactions

Transaction Details

This supplier has completedtransactions with buyers from .

Shipping Destination
Transaction Value
Transaction Date
Email to this supplier
The supplier supports Trade Assurance – A free service that protects your orders from payment to delivery.
Supplier's Trade Assurance Limit: US $
Learn More